Milwaukee MW180 MAX|MW150 MAX|MW151MAX|MW160 MAX Benchtop Meter

Multiparameter Water Analysis Benchtop Meter

MW150 MAX pH/ORP/Temp.

RANGE: -2.00 to 20.00 pH | ±2000.0 mV | -20.0 to 120.0°C (-4.0 to 248.0°F)
RESOLUTION: 0.01pH | 0.1mV | 0.1°C (0.1°F)
ACCURACY: ±0.01 ph | ±1 mV | ±0.4°C |±0.8°F

MW151MAX pH/ORP/Temp.Logging

RANGE: -2.00 to 20.00 pH / -2.000 to 20.000 | ±2000.0 mV | -20.0 to 120.0°C (-4.0 to 248.0°F)
RESOLUTION: 0.01 pH / .001 pH | 0.1 mV | 0.1°C (0.1°F)
ACCURACY: ±0.01 pH / ±0.002 ph | ±1 mV | ±0.4°C |±0.8°F
MW160 MAX pH/ORP/ISE/Temp.Bench Meter
RANGE: -2.00 to 16.00 pH | ±699.9 mV / ±2000 mV | 0.001 to 19999 ppm (ISE) | -20.0 to 120.0°C (-4.0 to 248.0°F)
RESOLUTION: 0.01pH | 0.1mV / 1 mV | 0.001 (0.001 to 9.999 ppm) / 0.01 (10.00 to 99.99) ppm / 0.1 (100.0 to 999.9 ppm) / 1 (1000 to 19999 ppm) | 0.1°C (0.1°F)
ACCURACY: ±0.01 pH | ±0.2 mV / ±1 mV | ±0.5% F.S. (ISE) |±0.4°C
Specifications
Range pH -2.00 to 16.00 pH; -2.000 to 16.000 pH
mV ± 699.9 mV; ± 2000 mV
EC 0.00 to 29.99 ?S/cm; 30.0 to 299.9 ?S/cm; 300 to 2999 ?S/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (uncompensed EC*)
TDS 0.0 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L actual TDS (with 0.80 factor)
NaCl 0.0 to 400.0 %
Temp -20.0 to 120.0 °C / -4.0 to 248.0 °F
Resolution pH 0.01 pH; 0.001 pH
mV 0.1 mV; 1 mV
EC 0.01 ?S/cm; 0.1 ?S/cm; 1 ?S/cm; 0.01 mS/cm; 0.1 mS/cm;
TDS 0.01 mg/L; 0.1 mg/L; 1.0 mg/L; 0.01 g/L; 0.1 g/L
NaCl 0.10%
Temp 0.1 °C / 0.1 °F
Accuracy pH ± 0.01 pH; ± 0.002 pH
mV ± 0.2 mV; ± 1 mV
EC ± 1 % of reading ±(0.05 ?S/cm or 1 digit)
TDS ± 1 % of reading ±(0.03 ppm or 1 digit)
NaCl ± 1 % reading
Temp ± 0.4 °C / ± 0.8 °F
Rel mV offset ± 2000 mV
Calibration pH 1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
EC 1 point slope calibration with 6 memorized solutions: (84 ?S/cm, 1413 ?S/cm, 5.00 mS/cm, 12.88 ?S/cm, 80.0 ?S/cm, 111.8 mS/cm)
NaCl 1 point, with MA9066 solution
Temp 2 point, at 0 and 50 °C / 32 and 122 °F
Temperature Compensation automatic or manual, from -20.0 to 120.0 °C / -4.0 to 248.0 °F
Temperature Coefficient selectable from 0.00 to 6.00 % / °C (EC and TDS only)
pH Electrodes & Temp Probe MA917B/1 & MA831R (included)
EC/TDS/NaCl/Temp Probe MA814DB/1 (included)
TDS Factor 0.40 to 0.80 (default value is 0.50)
Log on demand up to 50 samples on each range (pH, mV, EC, TDS, NaCl)
GLP last pH, EC, NaCl calibration data
PC Interface RS232 / USB Opto-isolated
Environment 0 to 50 °C / 32 and 122 °F; max RH 95 %
Input Impedance 1012 Ohm
Power supply 12 VDC power adapter (included)
Dimensions 230 x 160 x 95 mm
Weight 0.9 kg
 
2010 © Copyright PT. Digital Akurasi | Valid XHTML & CSS
Developed by